CIMI-902F
Series
Low Cost, 30Amp
PC Board Relay
w/QC Terminals
Technical Data
| Contact Parameters | |
| Initial Contact Resistance: | <50 milliohms |
| Resistive Contact Rating: | SPST-NO:30A @ 240Vac |
| SPST-NC:15A @ 240Vac/28Vdc | |
| SPDT-NO/NC:20A/10A @ 240Vac/28Vdc | |
| Contact Arrangement: | 1 Form A (SPST-NO), 1 Form B (SPST-NC) |
| 1 Form C(SPDT) | |
Insulation Characteristic |
|
| UL Class F insulation standard, meets UL 508 & UL 873 spacing requirements | |
| Insulation Resistance: | >500 M |
Dielectric Withstanding Voltage(RMS 50Hz) |
|
| Between Contacts: | 1,500 V |
| Between Coil and Contacts: | 2,000 V |
Environmental Characteristic |
|
| Temperature Range: | -55°C to 105 °C |
| Relative Humidity: | 98% @ 20°C |
| Shock Resistance: | 10g |
| Vibration Resistance: | 10 ~ 55Hz @ 1.5mm (Double Amplitude) |
Life Expectancy |
|
| Electrical: | 100,000 operations @ rated loads. |
| Mechanical: | 10 million operations |
Mechanical Data |
|
| Dimension: | 1.280 x 1.080x 1.103 inches max. |
| Termination: | PCB and 1/4" QC Terminals |
| Weight: | 33 grams Approx. |
Terminal Layout
|
|
|
|
Wiring
Diagram
|
Terminal
Layout
|
Coil Data
Coil Data @ 20 Degree C:|
Rated Voltage
(Vdc) |
Coil Resistance
(Ohms +/-10%) |
Pick-up
(Vdc) |
Drop-out
(Vdc) |
Coil Power
(mW) |
|
5
|
27
|
3.8
|
0.5
|
1,000
|
|
6
|
40
|
4.5
|
0.6
|
1,000
|
|
9
|
97
|
6.7
|
0.9
|
1,000
|
|
12
|
155
|
9.0
|
1.2
|
1,000
|
|
18
|
380
|
13.5
|
1.8
|
1,000
|
|
24
|
660
|
18.0
|
2.4
|
1,000
|
|
36
|
1,440
|
27.0
|
3.6
|
1,000
|
|
48
|
2,560
|
36.0
|
4.8
|
1,000
|
|
110
|
13,400
|
82.5
|
11.0
|
1,000
|
Ordering Information
|
|
|
CIMI -
|
902F
|
-1C
|
-S
|
-24D
|
(1100)
|
|
1
|
Basic Type:
902F
|
|
|
|
|
||
|
2
|
Contact
Arrangement:
|
|
|
|
|||
|
|
1A = 1 Form A (SPST-NO)
1B = 1 Form B (SPST-NC) 1C = 1 Form C (SPDT) |
|
|
|
|||
|
3
|
Cover Type:
|
|
|
||||
|
|
S=Epoxy Sealed
Blank=Unsealed |
|
|
||||
|
4
|
Coil Voltage:
|
|
|||||
|
|
D: 5, 6, 9, 12, 18,
24, 36, 48, 110Vdc
|
|
|||||
|
5
|
Coil
Resistance (may not appear on relay):
|
||||||
|
|
Blank: for
standard coils.
|
||||||
|
|
XXXX: last
4 digit of the actual coil resistance for all special coils.
|
||||||